The Sanwa CD772 is a True-RMS digital multimeter with a 4000-count display and thermocouple temperature measurement capability.

The CD772 is designed for measurements in the CAT II (1000 Volts) and CAT III (600 Volts) ranges. It has an accuracy of 0.5% with an input resolution of 0.1mV for DCV. The instrument has True-RMS capability that allows it to accurately measure AC sine waves that are not pure. The device features a 4000 count, large format display that makes it easy on the eyes, and a backlight for working in low light or dark environment.

Along with voltage, current, frequency, and capacitance measurement, the CD772 can also measure temperature using a K-type thermocouple sensor (-20℃~300℃). The device also features continuity test capability with a buzzer alarm and an LED indicator. The device has an Auto-power save mode that activates after 30 minutes of inactivity.

The device has an overall secure build, it is made using double molding with an outside made of elastic elastomer material, and is according to the IEC61010-1 CAT.III 600V / CAT. II 1000V standards. The test lead pins come with removable pin covers and should be kept covered when measuring in a CAT III environment.

Includes meter, rubber holster, instruction manual, one set of test leads and one K type thermocouple temperature sensor.

  • True AC RMS
  • 4000 Count Large Display with Backlight
  • 5% Accuracy
  • Range hold, Data hold, and Relative function
  • Auto and Manual range selection
  • Auto power save: Power save about 30 minutes after no operation
  • Continuity confirmed by the buzzer and red LED
  • Temperature measurements up to 300 ℃ (K type thermocouple temperature sensor)
  • Double molding with outside made of elastic elastomer material
  • IEC61010-1 CAT.III 600V / CAT. II 1000V certified

Specifications

    CD772

    Measuring Range

    Accuracy

    Resolution

    Input Impedance

    DCV

    400m/4/40/400/1000V

    ±(0.5%+2)

    0.1mV

    10M-100MΩ

    ACV

    4/40/400/1000V

    ±(1.2%+8)

    0.001V

    10M-11MΩ

    DCA

    400Ω/4000Ω/40m/400m/4/15A

    ±(1.4%+3)

    0.1ΩA

     

    ACA

    400Ω/4000Ω/40m/400m/4/15A

    ±(1.8%+6)

    0.1ΩA

    Resistance

    400/4k/40k/400k/4M/40M Ω

    ±(1.2%+5)

    0.1Ω

    Capacitance

    50n/500n/5μ/50μ/100μF

    ±(5%+10)

    0.01nF

    Temperature

    -20°C-300°C

    ±(3%+30)

    0.1°C

    Frequency

    5/50/500/5k/50k/100kHz

    ±(0.3%+3)

    0.001Hz

    Continuity

    Buzzer sounds and LED lights up at between 0Ω  and 85Ω (±45 Ω )Open voltage: Approx. 0.4V

    Diode test

    Open voltage: approx.1.5V

    Display Numeral display 4000
    Sampling rate 3 times/sec.
    Bandwidth 45~500Hz(4V range)、45~1kHz(40V range and above)
    Fuse 0.5A/1000V 30kA Φ6.35×32mm
    16A/1000V 30kA Φ10×38mm
    Battery R6Px2
    Battery life Approx.150h (manganese battery) at DCV range
    Size/Mass H166×W82×D44mm/360g
    Safety IEC61010 CAT.Ⅲ 600V / CAT.Ⅱ 1000V